Ditch Witch JT100AT User Manual

Page 196

Advertising
background image

JT100/JT100 All Terrain Operator’s

Manual

Service - 195

Startup/10 Hour

CMW

©

Check Pipe Lube System

Check pipe auto lubricator TJC level before
startup and every 10 hours of operation. Change
pail (1) as needed. See “Change Auto Lubricator
TJC Pail” on page 224 for procedure. Check pipe
auto lubricator spray nozzles (2) every 10 hours.
Ensure that nozzles are free of obstructions and
operate properly. Clean as needed.

Test Pipeloader Control Switches

Check control proximity switches before startup
and every 10 hours of operation and clean or
replace as needed.

To test

1.

Turn ignition switch to ON. Do not start
engine.

2.

Place metal object above target on each
switch.

3.

If yellow LED on switch lights, switch sensor
is working.

To adjust switch position

1.

Remove two nuts and screws from switch.

2.

Insert one or more shims (shown) under switch until yellow light comes on when switch passes under
row select pin.

3.

Reinstall screws and nuts.

NOTICE: Ditch Witch

®

tool joint compound is

specially formulated to work with Ditch Witch
pipe lubrication system. Use of other tool joint
compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 188 for more information.

Advertising
This manual is related to the following products: