250 hour, Drilling unit – Ditch Witch JT100AT User Manual

Page 210

Advertising
background image

JT100/JT100 All Terrain Operator’s

Manual

Service - 209

250 Hour

CMW

©

250 Hour

Drilling Unit

Change Engine Oil and Filter (initial)

Change engine oil and filter after 250 hours. If
using motor oil that does not meet Deutz
specifications DQCIII-LA, regular change interval
will be 250 hours. See page 185 for more
information about DEO specifications.

To change:

1.

While oil is warm, remove drain plug (2).
Drain oil and replace plug.

2.

Remove filter (3) and replace with new filter
each time oil is changed. Add DEO at fill (1).

Change JT Drilling Fluid Planetary Oil

Change every 250 hours. Remove oil at fill (1).
Add MPL until oil comes out level plug (2).
Replace plugs.

Location

Task

Notes

DRILLING
UNIT

Change engine oil and filter

initial service

Change JT drilling fluid planetary oil

MPL

LOADER/
DRIVER

Check swing drive gearbox oil level

MPL

IMPORTANT: Use oil specified in temperature chart found in “Recommended Lubricants/Service Key”
on page 188.

Advertising