Emergency exit, Override box – Ditch Witch JT100AT User Manual

Page 64

Advertising
background image

JT100/JT100 All Terrain Operator’s Manual

Controls - 63

Emergency Exit

CMW

©

Emergency Exit

Push rear window out and exit to rear of cab.

Override Box

1.

Drive override connector

2.

Drill override connector

3.

Drilling fluid flow override switch

4.

Thrust/pullback or right track override switch

5.

Rotation or left track override switch

Item

Description

Notes

1.

Drive override
connector

Allows drive function override
when box is attached.

Use switches 4 and 5 to control
tracks.

2.

Drill override connector

Allows drill function override
when box is attached.

Use switches 3, 4 and 5 to control drill
functions.

3.

Drilling fluid flow
override switch

To turn fluid on, move right.

To turn fluid off, move left.

Connect to drill connector (2) to
control fluid flow.

Advertising
This manual is related to the following products: