Ditch Witch JT100AT User Manual

Page 88

Advertising
background image

JT100/JT100 All Terrain Operator’s Manual

Prepare - 87

Plan Bore Path

CMW

©

Pipe-By-Pipe Bend Limits - Power Pipe

®

Forged

Pipe

(C)

Forward (B)

Deflection (A)

Pipe

(C)

Forward (B)

Deflection (A)

1

0 ft 7 in (0.2 m)

14 ft 12 in (4.6 m)

12

76 ft 8 in (23.4 m)

155 ft 12 in (47.5 m)

2

2 ft 3 in (0.7 m)

29 ft 11 in (9.1 m)

13

88 ft 11 in (27.1 m)

164 ft 8 in (50.2 m)

3

5 ft 1 in (1.6 m)

44 ft 7 in (13.6 m)

14

101 ft 9 in (31 m)

172 ft 5 in (52.6 m)

4

9 ft 1 in (2.8 m)

59 ft 1 in (18 m)

15

115 ft 1 in (35.1 m)

179 ft 2 in (54.6 m)

5

14 ft 1 in (4.3 m)

73 ft 2 in (22.3 m)

16

128 ft 12 in (39.3 m)

184 ft 11 in (56.4 m)

6

20 ft 2 in (6.2 m)

86 ft 11 in (26.5 m)

17

143 ft 3 in (43.7 m)

189 ft 6 in (57.8 m)

7

27 ft 4 in (8.3 m)

100 ft 1 in (30.5 m)

18

157 ft 10 in (48.1 m)

193 ft 1 in (58.8 m)

8

35 ft 5 in (10.8 m)

112 ft 9 in (34.4 m)

19

172 ft 7 in (52.6 m)

195 ft 6 in (59.6 m)

9

44 ft 6 in (13.6 m)

124 ft 8 in (38 m)

20

187 ft 7 in (57.2 m)

196 ft 9 in (59.9 m)

10

54 ft 8 in (16.6 m)

135 ft 11 in (41.4 m)

21

197 ft 0 in (60 m)

197 ft 0 in (60 m)

11

65 ft 2 in (19.9 m)

146 ft 4.5 in (44.6 m)

Pipe 10 is illustrated.