Ditch Witch JT100AT User Manual

Page 167

Advertising
background image

Systems and Equipment - 166

JT100/JT100 All Terrain Operator’s Manual

Hydratong Wrenches

CMW

©

1.

To join, apply tool joint compound to threads and hand tighten joint.

2.

Attach Hydratong in either the join or break position.

Attach chain tongs (1) to both sides of joint. Place tongs as close to joint as possible.

Remove snapper pins (2) from slide pins (3), and insert slide pins into wrench handles (4).

Attach each end of hydraulic cylinder (5) to slide pins and insert snapper pins.

3.

Remove all slack from wrench and joint.

4.

To join, scribe straight line across joint on both
sides of separating line (A).

5.

To join, scribe second line (B) on moveable side of
joint in the opposite direction of tightening action.
Refer to table for correct dimension.

Join

Break

IMPORTANT: Ensure arms are crossed before using wrench.

Connection

Dimension

transition sub to JT100 pipe

3/8” (9.5 mm)

transition sub to beacon
housing

3/8” (9.5 mm)

transition sub to JT100 All
Terrain pipe

7/16” (11 mm)

transition sub to
backreamer

3/8” (9.5 mm)

j07om071h.eps

A

A

A

A

B

B