7 accessories and spare parts – BINDER MK 115 User Manual

Page 101

Advertising
background image

MKF + MKFT (E3.1) 07/2014

page 101/114


Options / accessories (continued)
Water circle: condensate recycling
Calibration of temperature and humidity including certificate
Spatial temperature and humidity measurement including certificate
Spatial temperature measurement acc. to DIN 12880 and humidity measurement with 9 measuring points

at 25 °C / 77°F and 60% r.H. or at specified values, with measuring protocol and certificate
Qualification folder
*) A water supply (1 to 10 bar) is necessary for the installation of the humidifying and de-humidifying

system. If no suitable house water connection is available, you can manually supply water by filling a

freshwater can. Furthermore, a water drain in a max. distance of 3 meters / 9.8 ft. and a max. height of

1 meter / 3.3 ft. is required.

If the refrigerating machine is continuously operated, the lifetime of the condenser-fan is 2.3

years.


20.7 Accessories and spare parts

BINDER GmbH is responsible for the safety features of the unit only, provided skilled electri-

cians or qualified personnel authorized by BINDER perform all maintenance and repair, and if

components relating to chamber safety are replaced in the event of failure with original spare

parts. The user is responsible for any risks arising from using unauthorized accessories /

components.

Unit size

115

240

720

Description

Art. no.

Rack, stainless steel

6004-0008

6004-0097

6004-0102

Perforated rack, stainless steel

6004-0030

8009-0447

8009-0511

Reinforced rack, stainless steel, with rack lockings

8012-0709

8012-0605

8012-0684

Rack lockings (4 pieces)

8012-0620

8012-0620

8012-0620

Door gasket silicone inside

6005-0151

6005-0188

6005-0199

Door gasket silicone outside

6005-0152

6005-0157

6005-0173

Radial fan

5013-0088

5013-0089

5013-0089

Seal ring

6005-0224

6005-0225

6005-0226

6005-0221

6005-0222

6005-0223

6005-0221

6005-0222

6005-0223

Unit fuse (3 pieces internal), overload release B16A

5006-0069

5006-0069

--

Unit fuse (3 pieces internal), overload release B25A

--

--

5006-0072

Description

Art. no.

Thermal cut-off device 229 °C / 444 °F class 1

5006-0037

Water connection kit

8009-0135

Safety kit for water connection with hose burst protection device and reflux pro-

tection device

BINDER INDIVIDUAL

Customized Solutions

Program controller MB1, display

5014-0182

Program controller MB1, E/A board

5014-0117

Temperature sensor Pt 100 straight

5002-0021

MKFT: Temperature sensor 2xPt 100 straight

5002-0046

Humidity sensor

5002-0044

Data Logger Kit T 220

8012-0715

Data Logger Kit TH 100

8012-0718

Data Logger Kit TH 100/70

8012-0719