Unit size

115

240

720

Electrical data

IP-system of protection acc. to EN 60529

IP

20

20

20

Nominal voltage (+/-10%)

V

400 3N~

400 3N~

400 3N~

Power frequency

Hz

50

50

50

Nominal Power

kW

6.20

7.50

13.00

Energy consumption at +25 °C / 77°F and

60 % r.H.

Wh/h

1250

1500

2200

Power plug: CEE plug 5-poles

Amp

16

16

32

Over-voltage category acc.

to

IEC 61010-1

II

II

II

Pollution degree acc. to IEC 61010-1

2

2

2

Over-current release category B, 3 x internal

Amp

16

16

25

Electrical data of the voltage and frequency changer

IP-system of protection acc. to EN 60529

IP

23

23

23

Nominal voltage (+/-10%) 60 Hz (input side)

V

480 3N~

480 3N~

480 3N~

Nominal power

kW

9

9

13

Over-voltage category acc.

to

IEC 61010-1

II

II

II

Pollution degree acc. to IEC 61010-1

2

2

2

Fuse

A

16

16

25

Further information

Weight (empty)

kg / lbs.

330 / 728

415 / 915 635 / 1400

Weight (empty)

with optional compressed air dryer

kg / lbs.

345 / 761

430 / 948 650 / 1433

Filling weight of refrigerant R 404A

(1

st

stage cooling, GWP 3750)

kg / lbs.

1.60 / 3.53 2.20 / 4.85 4.00 / 8.82

Filling weight of refrigerant R23

(2

nd

stage cooling, GWP 12100)

kg / lbs.

0.32 / 0.71 0.40 / 0.88 0.87 / 1.92

Noise level

approx. dB(A)

62

65

69

Noise level with optional compressed air dryer

(short-term)

approx. dB(A)

85

85

85

Noise level with voltage and frequency changer

approx. dB(A)

67

67

67

1)

Lower values are valid at an ambient temperature of max. 25 °C / 77°F

2)

Depending on the set-point

3)

Units with voltage and frequency changer: Values reduced by 0.3 K/min each.

All technical data is specified for unloaded units with standard equipment at an ambient temperature of

+25 °C / 77 °F and a power supply voltage fluctuation of +/-10%. The temperature data is determined in

accordance to BINDER factory standard following DIN 12880, observing the recommended wall clear-

ances of 10 % of the height, width and depth of the inner chamber.
All indications are average values, typical for units produced in series. We reserve the right to

change technical specifications at any time.

If the chamber is fully loaded, the specified heating up and cooling down times may vary ac-

cording to the load.

Bringing a source of humidity into the inner chamber will affect the minimum humidity specifi-

cation and may affect the humidity accuracy.

Advertising
This manual is related to the following products: