MKF + MKFT (E3.1) 07/2014

page 30/114


Permissible ambient temperature range during operation: +18 °C / 64.4 °F to +32 °C / 89.6 °F. At

elevated ambient temperature values, fluctuations in temperature can occur.

The ambient temperature should not be substantially higher than the indicated ambient tem-

perature of +25 °C / 77°F to which the specified technical data relate. For other ambient condi-

tions, deviations from the indicated data are possible.

Permissible ambient humidity: 70 % r.H. max., non-condensing.

When operating the chamber at temperature set-points below ambient temperature, high ambient humidi-

ty may lead to condensation on the unit.

Installation height: max. 2000 m / 6.6 ft. above sea level.

A water tap (1 bar to 10 bar) is necessary for the installation of the humidification system. If no suitable

house water connection is available, you can manually supply water by filling the water can (chap. 4.2).

To avoid any possible water damage, provide a floor drain at the location of the device. Select

a suitable installation site to avoid any consequential damage by splashing water.

When placing several units of the same size side by side, maintain a minimum distance of 250 mm / 9.84

in between each unit. Wall distances: rear 300 mm / 11.81 in, sides 200 mm / 7.87 in. Spacing above the

unit of at least 200 mm / 7.87 in must also be maintained.

With optional compressed air dryer: Wall distance rear approx. 1 m / 3.28 ft so that it is possible to

read the status display of the compressed air dryer on the unit rear.

Units with voltage and frequency changer: rear wall distance of the alternating climate chamber ap-

prox. 1 to set up the voltage and frequency changer

CAUTION

Danger by stacking.
Damage to the units.

Do NOT place alternating climate chambers on top of each other.

To completely separate the unit from the power supply, you must disconnect the power plug. Install the

unit in a way that the power plug is easily accessible and can be easily pulled in case of danger.
With an increased amount of dust in the ambient air, clean the condenser fan several times a year. We

recommend checking the fan grid (behind the left maintenance access flap) every week. In case of visible

dirt accumulation, disconnect the unit and clean the fan grid by suction.
Avoid any conductive dust in the ambiance according to the unit layout complying with pollution degree 2

(IEC 61010-1).
The alternating climate chamber MKF / MKFT must not be installed and operated in potentially explosive

areas.

DANGER

Explosion hazard.
Danger of death.

Do NOT operate the unit in potentially explosive areas.

KEEP explosive dust or air-solvent mixtures AWAY from the vicinity of the unit.