Using a Script to Set-Up the Office Server


44

AXEL Office Server

The message 'Reboot in progress...' is then displayed on the operator
console, the Office Server is reset and the new set-up is implemented. If a
connection problem occurs, a time-out error message is displayed.

4.3 - OBTAINING A CONFIGURATION

To obtain an Office Server configuration, use the rsh command together with
the setup_get option. This command sends a list of all Office Server
parameters to standard output, which may be redirected to a file:

# rsh axname setup_get > /tmp/file <CR>

The message 'Load set-up in progress...' is displayed on the operator
console when the rsh command is processing. If a connection problem occurs,
a time-out error message is displayed.

When the set-up parameters are loaded, the message '

OK,

set-up sent

' is

displayed on the operator console. If other messages are displayed, refer to
Section 4.4.

The configuration file lists each set-up parameter. Refer to Appendix A.7 for a
detailed description of this file.

4.4 - ERROR MESSAGES

This section explains the error messages, which may appear (displayed on
standard error'), during operation of the rsh command.

Two error groups are distinguished:

- fatal errors: numbered from 100 to 106
- set-up warning errors: numbered from 200 to 206
- other warning errors: numbered from 211 to 215

Advertising