Definition of static security levels, Changing passwords – Omnia Audio Omnia.11 User Manual

Page 35

Advertising
background image

19

Definition of Static Security Levels

There are five different access levels available set with the User Level dropdown:

Access Level

Account

Default

Password

Description

Full Access

user

omnia

Same as current (1.2 and below) operating mode. Full access to

all screens and controls.

IO Edit

ioedit

omniaio

Read/write to everything in “Input” and “Output” blocks, and

the entire “Setup” screen. Allows selection, download and

upload of I/O Configs and Presets. Allows bank selection and

update.

Preset Edit

presetedit

omniapreset

Read/write to everything in all Processing blocks, and the

“System” block on the “Setup” screen. Allows selection,

download and upload of I/O Configs and Presets. Allows bank

selection and update.

Read Only

readonly

omniaread

Read only access to everything. Cannot change anything.

Cannot select, download or upload Presets or I/O Configs.

Cannot select banks or update software.

Preset Select

presetselect

omniasel

Allows selection of presets. Cannot select I/O Configs.

Cannot download or upload Preset or I/O Configs. Cannot

select banks or update software.

All passwords are user configurable from the front panel Setup / Security menu or from the Configuration page on

the remote webpage interface.

Each level is allowed to change its own password, by providing the old password and the new password twice.

Changing Passwords

To change the password, select the desired User Level. The default level is “Full Access” with default password:

“omnia”. To change this, enter the existing password into the “Old Password” box, the new password in both the

New Password” boxes and then touch the “Change Password” button. Be sure to make note of your new

password!

NOTE: This same password is also used for remote control access and can be changed from the remote webpage

interface as well.

Auto Lock when ON will automatically lock the front panel when the screensaver activates. The password will be

required at bootup and whenever exiting screensaver mode.

Lock when touched will lock the front panel immediately, requiring the password to regain access.

Change Level will bring up the unlock keyboard similarly to Lock but will not lock the unit immediately, allowing

you to change the User Level and input the appropriate password for that level. Touch or click Cancel to cancel

without making changes.