Limiters metering (summary tab), Limiters (basic tab), Limiters metering (summary tab) limiters – Omnia Audio Omnia.11 User Manual

Page 74: Basic tab)

Advertising
background image

58

Limiters Metering (Summary Tab)

Similarly to the AGC gain reduction meters, the 6

limiter band gain reduction meters show the

amount of limiter activity from the top down in dB

and the crossover frequencies in use are shown just

above the meters. Likewise, gating activity is

indicated by a bright yellow outline around each

gain-reduction meter.

Unlike the AGCs though, these meters will be

moving faster because the limiter section works on

peaks instead of the average levels like the AGCs.

Limiters Metering Screen (Summary Tab)

Limiters

(Basic Tab)

There are 4 variable controls in the Limiters menu area and all of them are “global”. That is, they affect all 6 limiter

bands simultaneously and equally.

The first global control is an overall Drive control

that allows you to adjust the amount of gain

reduction in the entire 6-Band Limiter section at

once. This is (conveniently) just like changing the

value of each control in the limiters crossover

(XO) by the same amount.

Next are Attack Time Offset, Release Time

Offset and Gate Threshold Offset controls. These

can adjust all 6 bands simultaneously relative to

the individual control settings in the Advanced tab.

Descriptions of the Attack, Release and Gate

functions are described in detail in the Advanced

tab section below.

Limiters Menu (Basic Tab)