Warning – Westermo MDI-112-F4G User Manual

Page 132

Advertising
background image

128

4.11 Warning

The switch provides several types of Warning features for you to remote monitor

the status of end devices or the change of your network. The features include
Fault Relay, System Log and SMTP E-mail Alert.

Following commands are included in this section:

4.11.1

Fault Relay

4.11.2 Event Selection
4.11.3 Syslog Configuration
4.11.4 SMTP Configuration

4.11.5 CLI Commands

4.11.1 Fault Relay

The switch provides two digital outputs, also known as Relay Output. The relay
contacts are energized (open) for normal operation and will close under fault

conditions. Fault conditions include Dry Output, Power Failure, Ethernet port Link

Failure, Ping Failure and Super Ring Topology Change. You can configure these
settings in this Fault Relay Setting. Each Relay can be assigned 1 fault condition.

Relay 1: Click on checkbox of the Relay 1, then select the Event Type and its

parameters.

Relay 2: Click on checkbox of the Relay 2, then select the Event Type and its
parameters.

Event Type: Dry Output, Power Failure, Link Failure, Ping Failure and Super Ring
Failure. Each event type has its own parameters and should also be configured.

Currently, each Relay can have one event type.