Westermo MDI-112-F4G User Manual

Page 136

Advertising
background image

132

4.11.2 Event Selection

Event Types can be divided into two basic groups: System Events and Port Events.
System Events are related to the overall function of the switch, whereas Port

Events related to the activity of the specific ports

System Event

Warning Event is sent when…..

Authentication Failure An incorrect password, SNMP Community String

is entered.

Time Synchronize

Failure

Accessing to NTP Server is failure.

Power 1 Failure

Selected Power ID is failure.

Power 2 Failure

Selected Power ID is failure.

Fault Relay

The DO/Fault Relay is on.

Super Ring Topology
Changes

Master of Super Ring has changed or backup
path is activated.

Port Event

Warning Event is sent when…..

Link-Up

The port is connected to another device

Link-Down

The port is disconnected (e.g. the cable is pulled
out, or the opposing devices turns down)

Both

Either of Link Up or Link Down

Advertising
This manual is related to the following products: