Command lines of the warning configuration – Westermo MDI-112-F4G User Manual

Page 140

Advertising
background image

136

Command Lines of the Warning configuration

Feature

Command Line

Relay Output

Relay Output

Switch(config)# relay 1

dry dry output

ping ping failure

port port link failure

power power failure

ring super ring failure

Note: Select Relay 1 or 2 first, then select the

event types.

Dry Output

Switch(config)# relay 1 dry

<0-4294967295> turn on period in second

Switch(config)# relay 1 dry 5

<0-4294967295> turn off period in second

Switch(config)# relay 1 dry 5 5

Ping Failure

Switch(config)# relay 1 ping 192.168.2.200

<cr>

reset reset a device

Switch(config)# relay 1 ping 192.168.2.200 reset

<1-65535> reset time

Switch(config)# relay 1 ping 192.168.2.200 reset

60

<0-65535> hold time to retry

Switch(config)# relay 1 ping 192.168.2.200 reset

60 60

Port Link Failure Switch(config)# relay 1 port

PORTLIST port list

Switch(config)# relay 1 port fa1-5

Power Failure

Switch(config)# relay 1 power

<1-2> power id

any Anyone power failure asserts relay

Switch(config)# relay 1 power 1

Super Ring Failure Switch(config)# relay 1 ring

Disable Relay

Switch(config)# no relay

<1-2> relay id

Advertising
This manual is related to the following products: