Configuring the loop protection action, Configuring the global loop protection action, Configuring an mst region – H3C Technologies H3C S12500-X Series Switches User Manual

Page 116

Advertising
background image

105

Configuring the loop protection action

You can configure the loop protection action globally or on specific ports. The global configuration
applies to all ports. The per-port configuration applies to the individual ports. The per-port configuration

takes precedence over the global configuration.

Configuring the global loop protection action

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure the global loop
protection action.

loopback-detection global action
shutdown

By default, the device generates a
log but performs no action on the

port on which a loop is detected.

Configuring the loop protection action on a Layer 2 Ethernet
interface

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter Layer 2 Ethernet interface

view.

interface interface-type
interface-number

N/A

3.

Configure the loop protection
action on the interface.

loopback-detection action { block |
no-learning | shutdown }

By default, the device generates
a log but performs no action on

the port on which a loop is
detected.

Configuring the loop protection action on a Layer 2 aggregate
interface

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter Layer 2 aggregate

interface view.

interface bridge-aggregation
interface-number

N/A

3.

Configure the loop protection

action on the interface.

loopback-detection action
shutdown

By default, the device generates
a log but performs no action on

the port on which a loop is

detected.

Advertising
This manual is related to the following products: