Configure Host B and Host D to be on the same IP subnet. For example, 192.168.200.0/24.

Verifying the configuration

# Verify that Host A and Host C can ping each other, but they both fail to ping Host B.
# Verify that Host B and Host D can ping each other, but they both fail to ping Host A.
# Verify that VLANs 100 and 200 are correctly configured on Device A.

[DeviceA-Ten-GigabitEthernet1/0/3] display vlan 100

VLAN ID: 100

VLAN type: Static

Route interface: Not configured

Description: VLAN 0100

Name: VLAN 0100

Tagged ports:

Ten-GigabitEthernet1/0/3

Untagged ports:

Ten-GigabitEthernet1/0/1

[DeviceA-Ten-GigabitEthernet1/0/3] display vlan 200

VLAN ID: 200

VLAN type: Static

Route interface: Not configured

Description: VLAN 0200

Name: VLAN 0200

Tagged ports:

Ten-GigabitEthernet1/0/3

Untagged ports:

Ten-GigabitEthernet1/0/2