Configuring a software exception handling method, Configuring an exception handling method, Displaying the exception handling method – H3C Technologies H3C S7500E Series Switches User Manual

Page 80

Advertising
background image

69

Task Command

Display alarms present on transceiver modules.

display transceiver alarm interface [ interface-type
interface-number
] [ | { begin | exclude | include }
regular-expression ]

Display the present measured values of the digital
diagnosis parameters for pluggable transceivers.

display transceiver diagnosis interface [ interface-type
interface-number
] [ | { begin | exclude | include }

regular-expression ]

NOTE:

The display transceiver diagnosis interface command cannot display information for some transceiver
modules.

For more information about transceiver modules, see H3C Mid-Range Series Ethernet Switches Pluggable

Modules Manual.
For more information about transceiver-related commands, see the command references for the S7500E
switches.

Configuring a software exception handling method

By default, an SRPU automatically reboots when instruction error, illegal address error, data overflow,
null pointer, reset, or any other software anomaly occurs. You can also configure the SRPUs to stay in the

error condition without taking any protective action to preserve the error information for identifying the

problem.

Configuring an exception handling method

When you configure an exception handling method, follow these commands:

If two SRPUs are used, the reboot of the active SRPU causes an active/standby switchover.

If one SRPU is used, the reboot of the active SRPU causes the entire switch to reboot.

An LPU always automatically reboots when it detects a software exception.

The exception handling action affects only the failed card.

To configure a software exception handling method for SRPUs:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure a software

exception handling method
for SRPUs.

system-failure { maintain |
reboot }

Optional.
By default, an SRPU reboots when
software exception occurs.

Displaying the exception handling method

Use the display system-failure command to display the exception handling method.

<Sysname> display system-failure

System failure handling method: reboot