5.1 Servo Drive Inspection and Maintenance

— 5-3 —

5.1.2 Servopack

For inspection and maintenance of the Servopack, follow the inspection procedures in the
following table at least once every year. Daily inspection of the Servopack is not required.

SGDF-

A1CS

DC24V

CN3

C

N

5

CN4

CN1/IO

CN2/PG

SERVOPACK

RDY

ALM

Item

Frequency

Procedure

Maintenance

Clean unit interior and

circuit boards

At least

once a year

Check for dust, dirt, and oil on

the surfaces.

Clean with

compressed air or

cloth.

Loose screws

At least

once a year

Check for loose terminal block

and connector screws.

Tighten any loose

screws.

Defective parts in unit

or on circuit boards.

At least

once a year

Check for discoloration, damage

or discontinuities due to heating.

Contact your Yaskawa

representative.

Part Replacement Schedule

The following parts are subject to mechanical wear or deterioration over time. To avoid failure,
replace these parts at the frequency indicated.

Part

Standard

Replacement Period

Replacement Method

Smoothing Capacitor

7 to 8 years

Test. Replace with new part if necessary.

Relays

---

Test. Replace if necessary.

Fuse

10 years

Replace with new part.

Aluminium electrolytic

capacitor

5 years

Replace with new part if necessary.

Note

Operating Conditions:

• Ambient Temperature: annual average 30°C

• Load Factor: 80% max.

• Operation Rate: 20 hours/day max.