Output → /clt cn1-8 – Yaskawa Sigma Mini User Manual

Page 50

Advertising
background image

APPLICATIONS

2.1.2 Torque Limitcont.

— 2-6 —

Using /CLT Signal

This section describes how to use contact output signal OUT2 as a torque limit output
signal.

Photocoupler output
Maximum operating voltage

per output: 30 VDC
Maximum output current per

output: 50 mA DC

+ 24 V

I/O power supply

CN1-8

/CLT

SG-COM

Servopack

CN1-3

Output /CLT CN1-8

Torque Limit Output

For Speed/Torque

Control and

Position Control

This signal indicates whether motor output torque (current) is being restricted.

ON status: The circuit between CN1-8 and

CN1-3 is closed.

CN1-8 is at low level.

Motor output torque is being restricted.

(Internal torque reference is greater than the

preset value.) Output torque is restricted to

the torque limit value.

OFF status: The circuit between CN1-8 and

CN1-3 is open.

CN1-8 is at high level.

Motor output torque is not being restricted.

(Internal torque reference is equal to or below

the preset value.)

Preset Value: Cn-08 (TLMTF)

Cn-09 (TLMTR)
Cn-18 (CLMI) : At /CL input

Note This function is changed to another function depending on the setting of the pa-

rameter Cn-2C.

How to Set Level 2: External Torque Limit

First, use a contact input signal to make the torque
(current) limit value set in the parameter valid. Torque
limit cannot be set separately for forward and reverse
rotation.

To use this function, always set bit 2 of memory switch
Cn-02 to 0 (standard setting). The contact input speed
control function cannot be used.

/CL

ON: CN1-*1 is at

low level.

Torque is restricted.

Limit value:

Cn-18

/CL

OFF: CN1-*1 is at

high level.

Torque is not restricted. Normal operation status.

2

Servopack

Without

torque limit

Speed

Torque

With

torque limit

Speed

Torque

/CL

CN1-*1

Advertising