BASIC OPERATION

1.3.3 Examples of Connecting Host Controllerscont.

— 1-22 —

Example of Connecting to MITSUBISHI AD75 Positioning Unit

Servopack for Position Control

CN2

CN1

+24V

CN1

1Ry

*1

+24VIN

/S-ON

PCO
SG

ALM

SG-COM

PULS
/PULS
SIGN
/SIGN
CLR
/CLR

PULSE

SIGN

CLEAR

PGO

DOG

STOP

READY

10
13

7

3

14
15
16
17
18
19

3

21

4

22

5

23

25

24

11

14

7

1

+

*1 The ALM signal is output for approximately two seconds when the power is turned ON. Consider this when

designing the power ON sequence.

Use the ALM signal to operate the alarm detection relay (Relay 1Ry) and turn OFF the power supply to the Servopack.

Note Only signals for the MITSUBISHI AD75 Positioning Unit and the Yaskawa Servopack are shown here.