6.2Measures to Satisfy the EMC Directive

— 6-7 —

Cable Connections

To be prepared by the user
Shell + plug: 54331-0201
(Molex Japan)

To be prepared by the user
Socket Connector: 54280-0800
(Molex Japan)

Blue

White/blue
Yellow

White/yellow
Green

White/green
Red

Black

Connec-

tor case

Connec-

tor case

Shield

6.2.6 Control I/O

Use cables with CN1 connectors for control I/O. When using connector kits, use shielded
cable for the CN1 cable and make sure to ground between the cable shield and connector
case. Connect the shield at the host controller properly.

6.2.7 Digital Operator and Monitoring by Personal Computer

Use the Digital Operator or personal computer (for monitoring) for trial operation only. Discon-
nect them during normal operation.

6.2.8 Cable Core