Yaskawa Sigma Mini User Manual

Page 52

Advertising
background image

APPLICATIONS

2.1.2 Torque Limit cont.

— 2-8 —

/CL

ON: CN1-*1 is at

low level.

Torque is restricted.

Limit value:

Cn-18

/CL

OFF: CN1-*1 is at

high level.

Torque is not restricted. Normal operation status.

Note This function is changed to another function depending on the setting of parame-

ter Cn-2C.

To use input signal /CL as torque limit input signals, set the following parameters.

Cn-2A

Input signal selection 1 (IN1)

CN1-1 input signal

Factory

Setting: 0

For Speed/Torque Control

and Position Control

Cn-2B

Input signal selection 2 (IN2)

CN1-2 input signal

Factory

Setting: 2

For Speed/Torque Control

and Position Control

The function of the input signal changes according to the setting, as shown in the follow-
ing diagram.

/P-CON

Servopack

/P-CON

/S-ON

/ALMRST

/CL

/CL

IN1, IN2

Setting

Meaning

0

/S-ON (Servo ON)

1

/P-CON (proportional control reference)

2

/ALMRST (alarm reset)

3

/CL (torque limit)

2

Advertising