Emerson Process Management ControlWave EFM 3808 User Manual

Page 210

Advertising
background image

F-10 / Appendix F

CI-ControlWave EFM

this signal to end an in progress nomination immediately, or to start the next period
immediately (see Manually Starting/Ending a Nomination Period).


Stop Mode
The Stop mode selection allows the user to automatically have the valve closed, i.e.,
shut-in on stop mode, or left in the last position upon reaching the target (or
programmed end period).


Daily Only Mode
When Daily mode is enabled, only the programmed start and end hours are used by the
ControlWave EFM; the Start/Stop days are ignored, i.e., nomination begins and ends
within a 24 hour period every day.

Alarm at a level of %
The Alarm at a level of % setting can be configured as percentage of Volume (MCF) or
Energy (MMBTU). This feature allows the ControlWave EFM to provide an alarm
(logical nomination alarm) or indication to an operator or computer that a specified
amount of target has been reached. The number entered (1 to 100) sets the percentage
at which the logical nomination alarm will occur. The status of this setting, i.e., whether
or not a nomination alarm has occurred, can be determined via the Alarm Status signal
(see Figure F-9).

Alarm

Status

When the amount specified in ‘Alarm at a Level of (%)’ is reached, the value of the
signal will be set true.


CURRENT NOMINATION PERIOD - This section allows the operator to view the

following information associated with a nomination which is currently in progress:


Start: day/hour

The actual time and day of the month when the current nomination period started is
displayed. This may be the programmed time or the time at which an operator manually
started a period.

Stop: day/hour

The programmed end time and day of the month at which the current nomination
period will end. If using the Fast approach mode, the period may end sooner, i.e., when
the target is reached. If using the daily nomination feature, the stop date (day) will
show 0 to indicate that only the hour matters.


Target value (x 1000)
The Target value provides the value of Volume/Energy to be delivered during this
period.


Amount Delivered (x 1000)

The Amount Delivered reading provides the actual amount of volume/energy delivered
so far during this period.


Percent elapsed time
This signal shows the percentage of time which has elapsed for the current nomination
period, e.g., 4 hours into a 100 hour nomination period would cause this value to be 4.0.