Appendix g, Radio ready installation guide – Emerson Process Management ControlWave EFM 3808 User Manual

Page 245

Advertising
background image

CI-ControlWave EFM

Appendix G - Radio Ready Installation Guide / G-1

Appendix G

RADIO READY INSTALLATION GUIDE

G1.1 GENERAL INTRODUCTION


Control
Wave EFM Electronic Flow Meters may be ordered "Radio Equipped," or “Radio
Ready.” Radio Ready units contain all hardware required to field install a Bristol provided
radio except the radio and radio installation hardware (such as screws, nuts and washers.
Radio Ready units will include either an Internal RF Radio Cable with Bulk Head Antenna
Connector or an Internal RF Radio Cable that mates to an optional Polyphaser
(Surge/Impulse Suppresser).

Radios are shipped with all necessary installation hardware and are to be secured to the
factory installed Radio Mounting Bracket which in turn mounts to the ControlWave EFM
Fabrication Panel.

ControlWave EFM Electronic Flow Meters may be equipped with one of the external
radios listed below or may be shipped with the hardware necessary to install one of these
radios at a future date. The term “external radio,” refers to those radios that mount on a
Radio Mounting Bracket instead of piggy-back on an Expansion Comm. Module.

MDS 4710A – Remote Data Transceiver (Radio)
MDS 4710B – Data Transceiver (Radio)
MDS 9710A Remote Data Transceiver (Radio)
MDS 9710B Data Transceiver (Radio)
MDS 9810 – Spread Spectrum Data Transceiver (Radio)
MDS entraNET 900 Extended Range IP Networking Transceivers
MDS i
NET 900 Ethernet Radio
MDS Transnet 900 - Spread Spectrum Data Transceiver
FreeWave Radio -
Spread Spectrum Data Transceiver Model FGRM-501X005


Radios are shipped with the following additional hardware:

MDS 4710A/B, MDS 9710A/B & MDS 9810 models are provided with four (4) 6-32 x 5/16
Pan Head Screws and a Power Connector.

MDS entraNET 900 Serial Remote and Ethernet Remote models are provided with four (4)
6-32 x 5/16 Pan Head Screws and a Power Connector.

MDS entraNET 900 Access Point and MDS iNET 900 (Remote Serial Gateway, Remote
Ethernet Bridge or Access Point/Remote Dual Gateway) models are provided with four (4)
6-32 x 5/16 Pan Head Screws and a Power Connector.

MDS TRANSNET radios are provided with four (4) 6-32 x 7/16 Pan Head Screws, four (4)
#6 Flat 5/16 O.D. Washers and four (4) 6-32 Hex Nuts and a Power Connector.

FreeWave radios are provided with eight (8) 6-32 x 5/16 Pan Head Screws and four (4) 6-32
x .500 F/F Standoffs.