F.8.1 Meter Run Archive Files


When View Archive has been selected, the Meter Run Archive Files WebBSI Web Page
will be displayed (see Figure F-23). Meter Run Archive Files Web Pages provide three
types of archive files, i.e., Hourly, Daily & 15 Minute for each of the four runs.

Figure F-23 - Meter Run Archive File Web Page (Hourly Archive Shown)


Meter Run Archive File Web page pushbuttons allow the user to Collect Data, Save
Parameters, Search Criteria, select Floating Point Format and show File Definition. Users
can select one of the following Archive Collection Parameters: File Number To Collect,
Select from oldest record or Freeze Date/Time. Users can select the archive file, (Hourly,
Daily or 15 Minutes) for the run in question by entering a number from 1 to 12 in the field
adjacent to File Number:

Meter

Run

Run ID

Hourly

Archive

Number

Daily

Archive

Number

15 Minute

Archive

Number

1 Run

1

1 2 3

2 Run

2

4 5 6

3 Run

3

7 8 9

4 Run

4

10 11 12


The Web page opens by default configured to view Archive 1 (R1_HOURLY). To view
another archive, the user will enter the desired archive number in the File Number: field
and then press the Collect Data button.

To save the collected archive data, the user would press the Save Parameters button. A
Save Parameters dialog box will appear which will allow the user to select the file name to
save the data as, and select the folder to save the data in. After selecting the file Name and
Path (each box) and checking Save Archive Data, the file will be saved by clicking OK on
the Save Parameters Dialog. The file saved is a binary file. To view the file, the user may
use the Data File Conversion Utility or the UOI Dump Utility (UOIDMP.exe).