Emerson Process Management ControlWave EFM 3808 User Manual

Page 57

Advertising
background image

CI-ControlWave EFM

Installation & Operation / 2-5

1. Remove the unit from its carton and install it at the assigned work site (see Section

2.3.1). Dimensions are provided in Section 4.6 of this manual.

2. Remove the SCM Module and after configuring its jumpers, install it into Control-

Wave EFM Base Assembly, chassis slot 1, i.e., the first slot from the left end of the
Base Assembly Chassis (see Section 2.3.2).

3. Remove the CPU Module. Make sure that the Lithium Backup Battery has been

enabled, i.e., Backup Battery Board Jumper JP1 should be installed (on its jumper
posts). After configuring the CPU Module’s DIP-Switches (see Section 2.3.3) install it
into ControlWave EFM Base Assembly, chassis slot 2, i.e., the second slot from the
left end of the Base Assembly Chassis.

4. Configure/Connect appropriate communication port(s) (see Section 2.3.3.2). Connect

COMM. Port 1 or 2 of the ControlWave EFM (depending on CPU Switch SW1
settings - see Section 2.3.3.1) to a Communication Port of a PC (typically PC COMM.
Port 1). Note: Also see Section 2.4.4.

5. Install I/O wiring to each I/O Module (see Section 2.3.4). Install a communications

cable to a Model 3808 Transmitter if required (see Section 2.3.8).

6. Install a ground wire between the Enclosure’s Ground Lug and a known good Earth

Ground (see Section 2.3.9.5).

7. Install the Bezel so that the I/O Modules are covered (see Section 2.3.11).
8. If required, install the RTD Probe (see Section 2.3.5).
9. Install the Rechargeable Lead Acid Battery and Solar Panel (if provided) (see

Sections (2.3.9.3 & 2.3.9.4).

10. Connect DC Power wiring to the ControlWave EFM SCM (see Sections 2.3.9.1 &

2.3.9.2).

11. Apply power to the ControlWave EFM. Now continue with Steps 2 through 7 below

(and Section 2.4.1) and the ControlWave EFM will be ready for on line operation.


Step 2. Software Installation on the PC Workstation


ControlWave Designer software will have to be installed on the PC if the ControlWave
EFM is to be utilized in an application other than that supported by the standard load.
This is accomplished by installing the ControlWave Designer Package from the Open
BSI CD ROM.

You must install the Open BSI Network Edition. For information on minimum system
requirements and more details of the installation, see the installation procedure in Chapter
2 of the Open BSI Utilities Manual (document # D5081).

If you have an older version of ControlWave Designer already installed:


Beginning with ControlWave Designer Version 3.3, the copy protection key (dongle) is
NOT required. Prior to installing ControlWave Designer 3.3 or newer, you MUST remove
the hardware dongle from the parallel port of your PC workstation. Otherwise, when you
subsequently start ControlWave Designer, it will operate only in ‘DEMO’ mode, and will
limit the available system resources.

IMPORTANT:

When you start ControlWave Designer, you will be reminded to register the
software. Unregistered software can only be used for a maximum of 30 days. For
more information on the registration process, see Chapter 2 of the Open BSI
Utilities Manual (document # D5081).

Advertising