Status – Fujitsu Siemens Computers BS2000/OSD User Manual

Page 17

Advertising
background image

U25339-J-Z126-1-7600

17

Controls and indicators

Control panel on the global storage cabinet

The information is shown on the LCD display in the following format:

Meanings:

Line

Display field

Display

Meaning

Line 1

Maintenance
mode

none

User mode

CE

Maintenance mode

CM

Hot system maintenance mode

Test mode

none

Normal mode

T

Test mode

SSU status

Pnnn

SSU switched off, battery not active: P000
SSU switched off, battery active: P001

P codes during the switching on and initial-
ization phase as well as when switching off:
P002 to P379

Bnnn

nnn shows the time in hours since the backup
battery became active after the network
failure.

CHK

SSU in check stop state

CNCT

SSU connected to a cluster

Line 2

FLAG Code

none

Normal state

FFFFFFFFFFFFFFFF

Message or error code:
this display is for the purposes of the service
department.

FFFFFFFFFFFFFFFF

CC C CCCC

CM
CE

T Pnnn

Bnnn
CHK
CNCT

Line 1

Line 2

FFFFFFFFFFFFFFFF

Displays in line 1

Displays in line 2

STATUS