Control panel on the global storage cabinet

Controls and indicators

POWER COMPLETE

This green light is lit up after the system power controller has terminated the switching
on sequence without any errors. The light is extinguished when the POWER OFF button
is pressed.

SSU CHECK

The display illuminates if there is an error in global storage. The buzzer sounds at the
same time.

BATTERY STATUS

These indicators indicate the state of the backup battery:

Potentiometer for volume

This is used to set the volume of the buzzer.

Potentiometer for brightness

This is used to set the brightness of the LCD display.

4.2.2

Button functions

LCD BACK LIGHT

The LCD display STATUS (background) is illuminated for five minutes when you press
this button. The lights go out immediately when you press this button again.

CANCEL / ALARM STOP

When this button is pressed, the buzzer in the control panel is stopped and the SSU
CHECK light is extinguished. If another malfunction occurs after the light is extin-
guished, e.g. a machine error or a malfunction in the power supply, the buzzer and the
SSU CHECK light are reactivated.

Name

Color

Meaning

Measure

BS

green

Backup battery is installed

BBON

green

Backup battery is active

BI

green

Backup battery is not available

DI

green

Data in the global memory are invalid

DS

green

Indicator is not in use

BE

yellow

Error in backup battery operation

Call service dept.

BF

yellow

Error in the backup battery

Call service dept.