PROGRAM LOAD FRAME PRESET1

Standard processing in SVP mode

The AUXILIARY FRAME: LOAD PRESET1 screen is displayed:

Figure 40: AUXILIARY FRAME : LOAD PRESET1 screen

You can reach this screen directly from the MODE SELECTION FRAME by
entering the frame code

AU5

in the

FUNCTION=>

field or the command

FR AU5

in

line 24 and pressing

.

START MODE =>

Enter

1

for automatic start of the BS2000.

IPL DEVICE

PRESET GROUP

A unit address from which the operating system is
loaded (IPL) must be entered in the input field for

PRESET GROUP

. A maximum of three further

addresses can be entered.
Entry in our example:

0108

.

POWER ON IPL =>

Enter

1

for automatic IPL after POWER ON.

INITIAL FRAME =>

Enter

2

for a detailed display of the LOAD FRAME.

Catalog parameters

Ê

Press the

key.

The values entered are saved and thus made known to the SVP. These settings are
accessed for each IPL.

----- AUXILIARY FRAME: LOAD PRESET1 ----- E02L01F

-START MODE- -IPL DEVICE-
==> 1
*1 START AUTO 1 PRESET GROUP -----------------+
*2 START FAST 2 CURRENT GROUP --------+ |
>3 START DIAL 3 UNIT ADDRESS -+ + +
*4 START A108 A108 0108
XXXX XXXX
XXXX XXXX
XXXX XXXX

-POWER ON IPL-
==> 1
*1 ENABLE
>2 DISABLE
-INITIAL FRAME-
==> 2
*1 LOAD FRAME(BASIC) *PF12 CATALOG
>2 LOAD FRAME(DETAIL) *PF9 GO TO LOAD PRESET-2

CL-0 CPU-0 CHP-0 RUN
M
FLAG CODE = F6C0C100 00000F00
LTG TAST

i

ENTER