Au5) auxiliary frame: load preset1 – Fujitsu Siemens Computers BS2000/OSD User Manual

Page 70

Advertising
background image

70

U25339-J-Z126-1-7600

User frames

Standard processing in SVP mode

6.4.8.5

(AU5) AUXILIARY FRAME: LOAD PRESET1

Figure 31: AUXILIARY FRAME: LOAD PRESET1 screen

You can predefine the execution of an IPL by making an entry in this frame and pressing

:

START MODE => Predefine the loading mode by entering the appropriate number and

comment for the BS2000 loading mode:

1

START AUTO

for automatic startup

2

START FAST

for fast startup

3

START DIAL

for dialog startup

4

START

not used

IPL DEVICE =>

Entries in this field specify from which device an IPL should be
executed.

1

PRESET GROUP

Up to four unit addresses can be entered in the input
field for PRESET GROUP. The operating system is
loaded from the first device (IPL). In the case of an
error, the IPL is executed by the next device listed.

POWER ON IPL =>

Here you determine the behavior of the SVP after an IMPL.

----- AUXILIARY FRAME: LOAD PRESET1 ----- E02L01F

-START MODE- -IPL DEVICE-
==> 1
*1 START AUTO 1 PRESET GROUP -----------------+
*2 START FAST 2 CURRENT GROUP --------+ |
>3 START DIAL 3 UNIT ADDRESS -+ + +
*4 START 08F7 08F7 0214
XXXX 00B0
XXXX XXXX
XXXX XXXX

-POWER ON IPL-
==> 2
*1 ENABLE
>2 DISABLE
-INITIAL FRAME-
==> 2
*1 LOAD FRAME(BASIC) *PF12 CATALOG
>2 LOAD FRAME(DETAIL) *PF9 GO TO LOAD PRESET-2

CL-0 CPU-0 CHP-0 RUN
M
FLAG CODE = F6C0C100 00000F00
LTG TAST

ENTER

Advertising