The Elite XL front panel 2-11

7. Interfaces —

Press the Enter key to access the two Interfaces submenus. One of the Interfaces

submenus, RS422 Serial, also has submenus.

Submenu

Description

Settings

Notes

8-pin serial

Determines the 8-pin serial
interface mode.

LocalTalk and RS422

If you change the 8-pin serial
setting,you must restart the
printer. In order for the RS422
submenu to appear in the display
window, you must set the 8-pin
serial submenu to RS422

RS422 Serial
(5 submenus)

RS422
Baud Rate

Determines the RS-422 baud rate.

300, 600, 1800, 2400,
3600, 4800, 7200, 9600,
19200, 38400, and
57600

RS422
Data Bits

Determines the number of data
bits sent with each serial byte.

8 and 7

RS422
Stop Bits

Determines the number of stop
bits sent with each serial byte.

1, 1.5, and 2

RS422
Parity

Determines the parity sent with
each with serial byte.

None, Even, and Odd

RS422
Flow Ctrl.

Determines which flow control
protocol will be used by the
RS-422 serial port.

XON/XOFF,
XON/XOFF Input, and
DTR

Always set to DTR when
sending a PCL job.