148

17

CONTROL COMMAND

17

• Command table (continued)

D To send/read memory contents

When sending or reading memory contents, additional code
as follows must be added to appoint the memory channel.
➥Additional code: 0000–0102

(0100=P1, 0101=P2, 0102=Call)

D Band stacking register

To send or read the desired band stacking register ’s con-
tents, combined code of the frequency band and register
codes as follows are used.
For example, when sending/reading the oldest contents in
the 21 MHz band, the code “0703” is used.
• Frequency band code

• Register code

D Codes for memory keyer contents

To send or read the desired memory keyer contents, the
channel and character codes as follows are used.
• Channel code

• Character’s code

1A

050114

Send/read NR level set
(0=0 to 15=15)

050115

Send/read VOX gain (0=0% to
255=100%)

050116

Send/read anti VOX gain (0=0% to
255=100%)

050117

Send/read VOX delay (0=0.0 sec.
to 20=2.0 sec.)

050118

Send/read DTMF speed set
(0=100 msec., 1=200 msec.,

2=300 msec., 3=500 msec.)

050119

Send/read Break-IN delay set
(20=2.0d to 130=13.0d)

06

Send/read SSB transmit band-
width (0=WIDE, 1=MID, 2=NAR)

07

Send/read DSP filter shape
(0= sharp, 1= soft)

08

Send/read manual notch filter1
bandwidth
(0=WIDE, 1=MID, 2=NAR)

09

Send/read manual notch filter2
bandwidth
(0=WIDE, 1=MID, 2=NAR)

0A

Send/read 9600 bps mode set
(0=OFF, 1=ON)

1B

00

Set/read repeater tone frequency
(see p. 149 for details)

01

Set/read TSQL tone frequency
(see p. 149 for details)

02

Set/read DTCS code and polarity
(see p. 149 for details)

1C

00

Set/read the transceiver’s condi-
tion (0=Rx; 1=Tx)

01

Set/read antenna tuner condition
(0=OFF, 1=ON, 2=Start tuning or

while tuning)

Command

Sub command

Description

Code

Frequency band Frequency range (unit: MHz)

01

1.8

1.800000– 1.999999

02

3.5

3.400000– 4.099999

03

7

6.900000– 7.499999

04

10

9.900000–10.499999

05

14

13.900000–14.499999

06

18

17.900000–18.499999

07

21

20.900000–21.499999

08

24

24.400000–25.099999

09

28

28.000000–29.999999

10

50

50.000000–54.000000

11

144

144.000000–148.000000

12

430

430.000000–450.000000

13

GENE

Other than above

Code

Registered number

01

1 (latest)

02

2

03

3 (oldest)

Code

Channel number

01

M1

02

M2

03

M3

04

M4

CW: Clockwise, CCW: Counter Clockwise

Character ASCII code

Description

0–9

30–39

Numerals

A–Z

41–5A

Alphabetical characters

space

20

Word space

/

2F

Symbol

?

3F

Symbol

,

2C

Symbol

.

2E

Symbol

^

5E

e.g., to send

BT

, enter ^4254

2A

Inserts contact number (can be
used for 1 channel only)