Removing a line card from an ex8200 switch – Juniper Networks EX8208 User Manual

Page 244

Advertising
background image

8.

Place the SF module in the antistatic bag or on the antistatic mat.

9.

If you are not replacing the SF module, install the cover panel over the empty slot
by tightening the screws on each side of the cover panel with the screwdriver.

Figure 86: Removing an SF Module from an EX8208 Switch

Related Topics

Installing an SF Module in an EX8208 Switch on page 157

Switch Fabric (SF) Module in an EX8208 Switch on page 28

Removing a Line Card from an EX8200 Switch

EX8200 switches have field-replaceable unit (FRU) line cards that can be installed in
the line card slots on the front of the switch chassis. The line cards are hot-insertable
and hot-removable: You can remove and replace them without powering off the switch
or disrupting switch functions.

Before you begin removing a line card from an EX8200 switch:

Ensure that you have taken the necessary precautions to prevent Electrostatic discharge
(ESD) damage (see “Prevention of Electrostatic Discharge Damage on EX Series
Switches” on page 292).

If there are any transceivers installed in the line card, remove them before you remove
the line card. See “Removing a Transceiver from an EX Series Switch” on page 222.

Ensure that you know how to handle and store the line card (see “Handling and Storing
Line Cards in EX8200 Switches” on page 227).

Copyright © 2010, Juniper Networks, Inc.

218

Complete Hardware Guide for EX8208 Ethernet Switches

Advertising