Table 25: Power Supply LEDs on EX8200 Switches

Description

State

LED

Indicates one of the following:

Power supply is disconnected from AC power feed.

AC power input voltage is not within normal
operating range.

No AC power input.

Unlit

INPUT OK

AC power input is high-voltage line (200–240 VAC).

Green

AC power input is low-voltage line (100–120 VAC).

Yellow

NOTE: This LED state
applies only to 2000 W AC
power supplies.

Indicates one of the following:

DC output voltage is not within normal operating
range.

Power supply is not supplying DC power correctly.

Unlit

OUTPUT OK

DC power output is within normal operating range.

Green

Power supply has been disabled internally by the
system.

Yellow

Power supply is functioning normally.

Unlit

FAIL

On steadily—Power supply has failed.

Blinking—Demand for output power exceeds the
supply.

Yellow

NOTE: If the

INPUT OK

LED and the

OUTPUT OK

LED are unlit, the AC power cord is not

installed properly or the power supply has failed.

If the

INPUT OK

LED is lit and the

OUTPUT OK

LED is unlit, the AC power supply is not

installed properly or the power supply has an internal failure.

If the

FAIL

LED is lit, the power supply has failed and must be replaced. If the

FAIL

LED

is blinking, add a power supply to balance the power demand and supply.

Related Topics

AC Power Specifications for EX8200 Switches on page 109

Power Requirements for EX8208 Switch Components on page 111

Power Requirements for EX8216 Switch Components

AC Power Cord Specifications for an EX8200 Switch on page 112

Connecting AC Power to an EX8200 Switch on page 173

47

Copyright © 2010, Juniper Networks, Inc.

Chapter 2: Component Descriptions

Advertising