Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting

May 2006

25. Turn the key switch to the Forced Off position. See the following figure.

!

DANGER:

!

DANGER:

Be sure to turn the key switch to the Forced Off position before handling any
internal components. Otherwise, it is possible for a user to restart the system
remotely while you are working inside it. The Forced Off position is the only key
switch position that prevents an RSC user from restarting the system.

26. Turn off the system monitor.

27. Turn off any external SCSI devices, starting with the device that is closest to the system

and working toward the farthest device.

28. Disconnect the tape drive from the SCSI port.

29. Turn on any external SCSI devices, starting with the device that is farthest from the system

and working toward the system.

30. Turn on the system monitor.

31. Turn on the system. Do not put the key switch in the locked position.

As the system powers up, the power LED on the monitor flashes.

32. Press Stop+A simultaneously as soon as the monitor power LED lights steadily and the

Sun logo is displayed on the monitor.

The ok prompt is displayed.

33. Enter the following commands:

setenv auto-boot? false

reset-all
The system resets.