Probing disk drives – Sun Microsystems Sun Fire V880 User Manual

Page 168

Advertising
background image

Troubleshooting

168

Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting

May 2006

Probing disk drives

This test checks all disk drives.

Symptom: The internal disk drives are reporting errors.

Solution: To check the status of the disk drives:

1. Enter:

/usr/sbin/shutdown -y -i0 -g0
This shuts down the system.

2. At the ok prompt, enter the following commands:

setenv auto-boot? false

reset-all
The system resets.

3. Enter:

probe-scsi
The program displays a message that is similar to the following:

Note:

Note:

The actual response depends on the number of disk drives that are installed in
the system. This example shows six disk drives and the disk drive backplane.

4. Fix any obvious errors, such as disconnected backplane cables or disk drives not

completely inserted.

5. When you finish testing, enter the following commands:

CAUTION:

!

CAUTION:

If you fail to enter these commands, any reboots that you do in the future will stop
at the boot prompt instead of proceeding through the normal boot-up process.

setenv auto-boot? true

boot -r
The system reboots.

LiD HA LUN

--- Port WWN ---

-----Disk description -----

0

0

0

21000004cf72f08f

SEAGATE ST373405FSUN3660438

1

1

0

21000004cf721553

SEAGATE ST373405FSUN3660438

2

2

0

21000004cf7213ea

SEAGATE ST373405FSUN3660438

6

6

0

508002000016b5b1

SUNW

SUNWGS INT FCBPL9224

3

3

0

21000004cf72114b

SEAGATE ST373405FSUN3660438

4

4

0

21000004cf7211ae

SEAGATE ST373405FSUN3660438

5

5

0

21000004cf7214a3

SEAGATE ST373405FSUN3660438

Advertising