Troubleshooting

172

Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting

May 2006

OpenBoot diagnostic tests

OpenBoot Diagnostics (OBDiag) is a menu-driven diagnostic tool that diagnoses system
hardware.

OBDiag performs root-cause failure analysis on the referenced devices by testing internal
registers, confirming subsystem integrity, and verifying device functionality.

To use the OpenBoot diagnostic tests:

1. From the root login, turn off CMS.

2. Enter:

/usr/sbin/shutdown -y -i0 -g0
The system shuts down and the ok prompt is displayed.

3. Set the key switch to the diagnostics position.

4. At the ok prompt, enter the following commands:

setenv auto-boot? false

reset-all
The system resets.

5. Enter:

obdiag
This loads the test program and the test menu is displayed.

6. Do one of the following:

On the V880, enter:

obtest <command number>

On the V890, enter:

test <command number>

See

Test descriptions

on page 173 for a description of each command.

7. When finished with testing, set the key switch to the normal position.

8. Enter the following commands:

setenv auto-boot? true

reset-all