Performing loop diagnostic tests, Procedure 47, Ven in table 41 on – Nortel Networks M3110 User Manual

Page 300

Advertising
background image

Page 300 of 504

Digital telephones line engineering

553-3001-367 Standard 3.00 August 2005

2

Add the total of all cable sections. If the total of all sections exceeds
175 ohm, select another loop.

Note: The loop resistance limit of 175 ohm must be reduced by 1 ohm for
each percent of the loop that is aerial cable (see Table 41 on

page 300

).

Performing Loop Diagnostic Tests

The following equipment is required for the loop diagnostic tests in
Procedure 47 on

page 300

:

one volt-ohmmeter (VOM) for each test

one 77 cable analyzer or equivalent for each test

Procedure 47
Testing foreign voltage

1

Set the VOM range switch to a scale 60 V DC/V AC or greater.

2

Connect the VOM test probes to the loop at the line card or distributing
frame.

3

Measure the DC and AC voltage between the following points under
no-load conditions:

tip (T) and ring (R)

T and ground (GND)

R and GND

Requirement: Voltage readings should be less than 1 V DC/V AC.

Table 41
Conductor resistance per unit

Gauge

Ohm per loop kft

Ohm per loop km

26

83

278

24

52

173

22

33

109

19

16

54