Nortel Networks M3110 User Manual

Page 436

Advertising
background image

Page 436 of 504

Appendix C: Meridian Modular Telephones add-on modules installation

553-3001-367 Standard 3.00 August 2005

4

Be sure the transformer is plugged in, or the closet
power is connected.

5

Be sure the cable between the MCA and the
telephone is connected and has not been pinched.

6

Be sure the power card is installed correctly. Verify
that the jumper settings are correct for either RS-232
or V.35 (whichever you are using).

Key Expansion Module does
not work.

1

Unplug and plug in the line cord.

2

Ensure that the transformer is plugged in or that the
closet power supply is connected.

3

Ensure that the power supply board is installed
properly.

4

Make sure that the ribbon cable connecting the
telephone and the Key Expansion Module is routed
properly and is not pinched.

External Alerter does not work.

1

Ensure that the External Alerter Board is installed
properly.

2

Check that connections between the alerting device
and the telephone connecting block are correct.

3

Make sure that the jumpers are placed on the pins on
the External Alerter Board as described in
Procedure 76 on

page 416

.

4

Ensure that the transformer is plugged in or the closet
power is connected.

Table 72
Troubleshooting Meridian Modular Telephones (Part 4 of 5)

Symptom

Solution

Advertising