Appendix E: M3110, M3310, and M3820 telephones

553-3001-367 Standard 3.00 August 2005

Note 1: All terminals must be isolated from the input winding and each
terminal must be isolated from all other terminal windings. A separate
winding is required for each terminal, and grounds must not be
connected.

Note 2: The QUT1 closet power supply source is not compatible with
Meridian digital telephones.

The AC source must be rated at 29 V AC, 700 mA isolated. The DC source
must be rated at 42 V DC, 300 mA isolated, with current limiting output of 1
amp.

Figure 103
Closet Power Supply configuration

1

2

3

4

5

6

W

BL

6-conductor

line cord

from telephone

To IDF

Tip (r)

Ring (g)

Closet Power Supply

(Shumway SBI 221-25 or equivalent)

Connects to an

isolated output

553-AAA0724