Normal operating ranges, Installation, Packing and unpacking – Nortel Networks M3110 User Manual

Page 59: See table 5 on

Advertising
background image

Attendant consoles

Page 59 of 504

Telephones and Consoles

Description, Installation, and Operation

7

Terminate leads at the cross-connect terminal and designate the blocks
according to the house cable plan.

Normal operating ranges

The M2250 attendant console has a maximum permissible loop length of
3500 ft (915 m), assuming 24 AWG (0.5 mm) wire with no bridge taps. A
15.5 dB loss at 256 kHz defines the loop length limit.

Installation

This section provides installation instructions for the M2250 attendant
console. For Attendant PC Software installation instructions, refer to
Meridian 1 Attendant PC: Software Installation Guide.

Packing and unpacking

Use proper care while unpacking the M2250 attendant console. Check for
damaged containers so that appropriate claims can be made to the transport
company for items damaged in transit.

Table 5
Terminal connections

Connecting block

Designations

Inside wiring

Colors

NE-47QA or

QBB1B

NE-284-74-500

1 adapter

NE-625F

TELADAPT

plugs and jacks

Z station wire

16/25-pair cable

G

1T

T1 (G)

G

W-BL

R

1R

R1 (R)

R

BL-W

BK

X1

AUX (BK)

BK

W-O

Y

X2

GND (Y)

Y

O-W

5

R

T2 (BL)

W-SL

6

B

R2 (W)

SL-W