Procedure 48 testing insulation resistance, Procedure 49 testing dc continuity, Procedure 50 testing capacitance unbalance – Nortel Networks M3110 User Manual

Page 301

Advertising
background image

Digital telephones line engineering

Page 301 of 504

Telephones and Consoles

Description, Installation, and Operation

Procedure 48
Testing insulation resistance

1

Set the VOM range switch to ohm x 10,000 and adjust the meter to zero.

2

Connect the VOM test probes to the loop at the line card or distribution
frame.

3

Measure the resistance between the following points under no-load
conditions:

T and R

T and GND

R and GND

Requirement: Resistance readings must be greater than 10 M ohm.

Procedure 49
Testing DC continuity

1

Short circuit the T and R at the far end.

2

Using the VOM, measure the resistance between the T and R.

Requirement: Resistance measurement should be approximately
equal to the calculated loop resistance as described in Procedure 46
on

page 299

.

Procedure 50
Testing capacitance unbalance

1

Using the cable analyzer, measure the capacitance between the following
points:

T and GND

R and GND

Requirement: The difference between the two readings must be
<0.002 µF>.

Advertising