Digital telephones line engineering

Page 305 of 504

Telephones and Consoles

Description, Installation, and Operation

6

Reject loops whose expected pulse loss is greater than 12 dB.

Example of applying Procedure 53

Section 1:

Mainframe bulkhead to DF1 - 500m, 26 AWG PIC, underground

Section 2:

DF1 to DF2 - 200m, 26 AWG PIC, inside

Section 3:

DF2 to terminal - 24 AWG NT D-inside

Therefore:

SL1 = 1.5 km, SL2 = 0.2 km, SL3 = 0.1 km

From Table 42 on

page 305

and Table 43 on

page 306

:

L1 = 13.7 dB/km, L2 = 13.7 dB/km, L3 = 13.3 dB/km.

Using the equation in Step 2, we arrive at the following:

CSL1 = 6.85 dB, CSL2 = 2.74 dB, and CSL3 = 1.33 dB

Temperature corrections:

Using correction factors of TCF1 = 1.04, and TCF2 and TCF3 = 1,

and using the equation in Step 3 results in TCL1 = 7.12 dB,
TLC2 = 2.74 dB, and TCL3 = 1.33 dB.

Expected pulse loss (EPL) value:

Neglecting any junction loss (see the note in Step 4), Step 5

results in an EPL value of TSL1 + TSL2 + TSL3 + 0 = 11.19 dB.

This is under the 12 dB limit and meets the criteria.

Table 42
Cable attenuation at 256 kHz and 21.1 degrees C (70 degrees F)

Cable

type

26 AWG

24 AWG

22 AWG

19 AWG

dB/kft

dB/km

dB/kft

dB/km

dB/kft

dB/km

dB/kft

dB/km

PIC

4.2

13.7

3.1

10.2

2.5

8.1

1.7

5.6

Pulp

4.3

14.3

3.5

11.4

2.7

9.0

2.0

6.6