Appendix B: Meridian Modular Telephones installation

553-3001-367 Standard 3.00 August 2005

Procedure 65
Designating Meridian Modular Telephones

1

Remove the cap from each key requiring a designation.

2

Place the designation in the cap, place the cap over the corresponding
key, and gently press down. Repeat for all keys requiring designations.

3

Insert a paper clip into the hole at the left or right end of the designation
window.

4

Gently pry the window toward the center and remove, and insert the
number tag.

5

Replace the designation window.

End of Procedure

Cross-connect the telephones

Follow the steps in Procedure 66 to cross-connect the telephones. Refer to
Figure 64 on

page 370

for an illustration of cross-connections.

Procedure 66
Cross-connecting the telephones

1

Locate the telephone terminations at the cross-connect terminal.

Telephone terminations are located on the vertical side of the frame when
frame-mounted blocks are used and in the blue field when wall-mounted
blocks are used.

2

Connect Z-type cross-connecting wire to the leads of the telephone. See
Table 63 on

page 369

and Table 64 on

page 369

.

3

Locate the line circuit card (TN) terminations.

Line circuit card (TN) terminations are located on the horizontal side of the
distributing frame when frame-mounted blocks are used and in the white
field when wall-mounted blocks are used.

4

Run and connect the other end of the cross-connecting wire to the
assigned TN terminal block.

End of Procedure