About this appendix – Nlynx ETU400 User Manual

Page 235

Advertising
background image

ETU400 User Guide 011603

D-12

11.

Display the next statement number by typing I1 over the first two

positions of the line containing statement 0004.00 and pressing Enter.

When the new statement line is displayed, press F4 to display a prompt in

which to enter the input specification.

12.

The field statement number 0005.00 screen appears. Here you will

define the third field in the SAMPLE file. Enter the data exactly as

shown in the data area prompt at the bottom of screen, as shown in Figure

D-7, and then press ENTER.

Figure D-7 SEU Edit screen for line 0005.00

Columns . . . : 1 80 Edit
QGPL/QRPGSRC
SEU==>
SAMPLE
FMT F .....FFilenameIPEAF....RlenLK1AIOvKlocEDevice+......KExit++Entry+A....U1........

*************** Beginning of data **********************************************
0001.00 FSAMPLE IP F 128 DISK
0002.00 ISAMPLE NS
0003.00 I 1 17 NAME
0004.00 I 18 52 TITLE
0005.00
****************** End of data *************************************************

Prompt type . . . ** Sequence number . . . 0005.00

Data area

....+... 1 ...+... 2 ...+... 3 ...+... 4 ...+... 5 ...+... 6.

I 53 602SALARY

F3=Exit F4=Prompt F5=Refresh F11=Previous record

F12=Cancel F23=Select prompt F24=More keys

Column 6 is the Form Type and must contain the letter I, which designates
this record as an input specification.

Use columns 44 through 47 to enter the beginning position of the Salary

field. This field starts at position 53.