Nlynx ETU400 User Manual

Page 258

Advertising
background image

ETU400 User Guide 011603

E-20

PROBLEM

Trying to install software gets this message: “SYS-2594 ETUXFER Trying to Copy Privileged
Module PCRCB1 not found
”.

CAUSE:

Customer installed the ETU 36 software but not as a security officer.

SOLUTION:

The installation requires some privileges that require the use of the security officer privileges. There
is no work around as these capabilities are external to ETU and is intrinsic to the SSP.

If a person lost the Security Officer password, the whole drive would have to be reformatted.

Advertising