Figure 205 power down cc-sg in diagnostic console – Raritan Computer CC-SG User Manual

Page 217

Advertising
background image

C

HAPTER

12:

A

DVANCED

A

DMINISTRATION

203

Powering Off the CC-SG System (Admin)
This option will power down the entire CC-SG. Users will not receive a notification. CC-SG,
SSH, and Diagnostic Console users (including this session) will be logged off. Any connections
to remote target servers will also be terminated. The only way to power the CC-SG unit back on
is to press the power button on the front panel of the unit.

To power off the CC-SG:

1. Click Operation, Admin, and then click CC-SG System Power OFF.

2. Either click Power OFF the CC-SG or press ENTER to remove AC power from the

CC-SG. Confirm the power down operation in the next screen to proceed.

Figure 205 Power Down CC-SG in Diagnostic Console

Resetting CC-SG (GUI) Admin Password (Admin)
This option will reset the password for the admin account CC-SG GUI user to the documented
factory default value.

Note: This is not the password for the Diagnostic Console admin user. Please refer to DiagCon
Passwords below for information about changing this account’s password.