6-40

Chapter 6: Programming

Model 801GC, 801GF & 801GX¥Rev. A

Pressing the Mode button cycles the power-on se-
quence mode settings as indicated by the “Mode”
label to the right of the sequence name at top of the
screen. The following settings are avaiable:

No label:

The sequence is not selected to to be the

power-on sequence.

Step:

The steps are manually selected with the bot-

tom knob, with stops at both ends of the list.

Wrap:

The steps are manually selected with the

bottom knob. Going past the last step jumps to
the first step and vice versa.

Auto:

The sequence automatically and continously

cycles through all the steps. The individual
“Delay” settings for each step determine how
long the generator pauses at each step.

Step-Display

, Wrap-Display and Auto Display: Work

the same way as the previous choices with the
addition of the step number being added to each
test image.

Only one sequence file can be the “Power-on”
sequence file at a time. Making the sequence you
are editing the “Power-on” sequence will deac-
tivate the “Power-on” mode status of all other
sequence files in memory. If no sequence is se-
lected as the “Power-on” sequence, the 801G*
will then power-up in the “Normal” operating
mode.

Pressing the Save button shows a window with the
name that will be used to save the sequence file to
non-volatile memory. The original file name is shown.
Saving back to the same file name will overwrite
the original contents. If you wish to keep the origi-
nal version of your sequence, you need to change
the name in the window using the knobs and but-
tons. Saving a new sequence file does not automati-
cally add it to the sequence knob directory.