6-114

Chapter 6: Programming

Model 801GC, 801GF & 801GX¥Rev. A

DSCT

Digital Sync Composite Type

Classification:

Format parameter setting

Command Syntax:

DSCT <type>

Limits:

<type>

0 = none
1 = American HDTV ORed
2 = American ORed
3 = American w/serr
4 = American w/serr & eq
5 = European HDTV ORed
6 = European ORed
7 = European w/serr
8 = European w/serr & eq
9 = American HDTV w/serr

10 = American HDTV w/serr & eq
11 = European HDTV w/serr
12 = European HDTV w/serr & eq
13 = Japanese HDTV ORed
14 = Japanese HDTV w/serr
15 = Japanese HDTV w/serr & eq

Query Syntax:

DSCT?

Query Response:

<type>

Description:

The DSCT command establishes the type of composite sync that
appears at the digital composite sync outputs when digital
composite sync is selected via the SSST command. The DSCT?
query returns the current setting of DSCT. A setting of zero (0)
indicates that digital composite sync cannot be activated by the
operator.

Other Required Cmds:

The FMTU command instructs the generator to use the new

setting. The ALLU command updates hardware to the new setting
and redraws the test image.

Example:

D S C T 2 / / S e l e c t s i m p l e A m e r O R e d i n
/ / b u f f e r

F M T U / / U p d a t e h a r d w a r e t o c u r r e n t

/ / b u f f e r c o n t e n t s