8-7

Format Error Messages

2030

SCAN less than 1

An invalid scan setting exists in the file.

Reedit the scan setting.

2040

SCAN greater than 2

An invalid scan setting exists in the file.

Reedit the scan setting.

2050

Horizontal total too small

The generator does not support a horizontal period (active
+ blanked) less than 144 pixels per horizontal scan line.

Increase the horizontal period so that it’s more than
143 pixels.

2060

Horizontal total too large

The generator does not support a horizontal period (active
+ blanked) of more than 4096 pixels per horizontal scan
line.

Decrease the horizontal period so that it’s less than
4096 pixels.

2071

Pixel rate too high

The pixel rate exceeds the maximum rate supported by the
currently selected generator model for the given video type
selection.

Make sure video type is correct.

Decrease the pixel rate.

Decrease the horizontal period (in pixels) for a given
horizontal rate.

2072

Pixel rate too high

The pixel rate exceeds the maximum rate supported by the
currently selected generator model for the given video type
selection.

Make sure video type is correct.

Decrease the pixel rate.

Decrease the horizontal period (in pixels) for a given
horizontal rate.

Advertising